top of page

2-1/2 inch with Brass Cap

SKU 299345073
Original price

$499.00

Sale price

$345.00

Excluding Sales Tax

|

So you have a water storage tank. Great!

You want to make it available to fire crews, and to use it to connect to your Fyrewagon pump.

Create a "Draft Hydrant" by connecting this 2-1/2 inch fire hydrant valve to your storage tank using schedule 40 PVC underground pipe.

What is a Draft Hydrant?

A Draft Hydrant is essentially an extended connection point of your water storage tank. It is best if the hydrant is above the elevation of your storage tank, or no more than 10-feet from the bottom of the tank to the top of your hydrant. This allows a fire crew to suck the water into their fire truck to use during a fire. Think of this as just an extended suction hose running to your tank.

For your use, A FyreWagon suction hose must be primed so in order to work the water has to start out being above the hydrant level. Once the pump is primed, it can maintain suction (or "draft") until the tank is empty.

We suggest using a 2-1/2 inch schedule 80 "bulkhead" fitting from the tank, close to the bottom. Add a 2-1/2 inch ball valve at the tank for maintenance of the Draft Hydrant system.

Planning the location of your Draft Hydrant

Fire crews want the Draft Hydrant to be located no more than 5-feet from the edge of your driveway. The hydrant should face straight towards the driveway and be mounted onto a sturdy 4x6 pressure-treated post set at least 2-feet into the ground.

Slope is important

For optimum use with our FyreWagon, the pipe should slope downward from your storage tank to automatically prime the pump (or, at a minimum, the valve should be below the tank's water level at startup to force water into the pump without priming). The pipe should be buried at least 12-inches below finish grade, and shaded with fine soil or sand compacted backfill. Install the pipe at least 18-inches in areas that will have vehicle traffic, and below the frost line in freezing climates.

In cold climates, the lowest point of the line should have a drain to winterize the line, or insulate the pipe above grade to keep it from freezing. All above-ground plastic pipe should be protected from UV exposure.

Check your local codes for additional requirements, as they differ from location to location and your fire department may have additional requirements. Some are so onerous that they make the cost of installing a Draft Hydrant beyond the means of a typical household.

What we provide:

We sell you the valve, the cut Uni-strut, the lag screws, and the fittings to connect to your 2-1/2 inch pvc water line. I like to use one size larger coupler (3-inch) and add 3x2-1/2 inch bushing (slip x female pipe threads) as the pvc to galvanized nipple connection. This method doubles the thickness of the coupler, making for a stronger connection. Do not use a pvc female adapter! (I will share war stories on why). We also provide the required 2-1/2 inch NH female x 2-inch female Cam-lock fitting adapter to attach your FyreWagon suction hose to the hydrant.

You'll need to buy:

1- 2-1/2 inch (or larger if unavailable) threaded bulkhead tank fitting

1- 4x6 pressure-treated post, 6-feet long

1- 2-1/2 inch x 36-inch galvanized schedule 40 metal pipe nipple (threaded on both ends)

2-2-1/2 inch schedule 40 ball valves (one to install at your storage tank, and one close to the hydrant)

1- small irrigation control box (typically green with a plastic lid)

2-1/2 inch schedule 40 pvc pipe and fittings to run from hydrant to your tank (plan on at least 10-feet extra)

Heavy-bodied glue (such as Weld-on 711 gray or similar). Don't use Rain or shine or damp glue, as these are more brittle and professionals just don't use that type.

Purple or clear pvc primer

These products are not going to be at your big box or local hardware store. You'll need to find an irrigation supply house that sells to contractors. Sweet talk them or find a contractor to order for you if they are strictly wholesale.

The Draft Hydrant output side is 2-1/2 inch and connects perfectly to our NH type fire hose connections (also a USA standard).

Placing a dedicated hydrant loop around your property eliminates long hose runs and offers you very rapid deployment of fire sprinklers or a fire hose to drench landscapes in a hurry.

Remember, this is not a pressurized hydrant! It is intended to FEED water to a fire truck or to your FyreWagon pump. If you are planning a pressurized hydrant system on your property, see our info under 1-1/2 hydrants. As always we are here to help you plan your system!


 